Màn hình kích thước 7.5inch, TFT Color LCD
Giá : Liên Hệ
GP-4401T (Model No.: PFXGP4401TAD)
*1: Other font sizes can be set up with the Editor software.
*2: Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
*3: Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec/month.
For systems where this level of deviation is a problem, the user should monitor and make adjustments when required
|
Rated Input Voltage |
DC 24 V |
|
|
|
|
|
|
Input Voltage Limits |
DC 19.2 to 28.8 V |
|
|
|
|
|
|
Allowable Voltage Drop |
5 ms or less |
|
|
|
|
|
|
Power Consumption |
12 W or less |
|
|
|
|
|
|
In-Rush Current |
30 A or less |
|
|
|
|
|
|
Voltage Endurance |
AC 1,000 V, 20 mA for 1 min (between charging and FG terminals) |
|
|
|
|
|
|
Insulation Resistance |
DC 500 V, 10 MΩ or more (between charging and FG terminals) |
|
|
|
|
|
|
Surrounding Air Temperature |
0 to 55 °C [32 to 131 °F] |
|
|
|
|
|
|
Storage Temperature |
-20 to 60 °C [-4 to 140 °F] |
|
|
|
|
|
|
Ambient Humidity |
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] or less - no condensation.) |
|
|
|
|
|
|
Storage Humidity |
||
|
|
||
|
|
|
|
|
Dust |
0.1 mg/m³ (10-7 oz/ft³) or less (non-conductive levels) |
|
|
|
|
|
|
Pollution Degree |
For use in Pollution Degree 2 environment |
|
|
|
|
|
|
Atmosphere |
Free of corrosive gases |
|
|
|
|
|
|
Air Pressure (altitude range) |
800 to 1,114 hPa (2,000 m above sea level or less) |
|
|
|
|
|
|
Vibration Resistance |
IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 |
|
|
Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (approx. 100 min) |
||
|
|
|
|
|
|
|
IEC/EN61131-2 compliant 147 m/s², X, Y, Z directions for 3 times |
|
Concussion Resistance |
||
|
Noise Immunity |
|
Noise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns (via noise |
|
|
simulator) |
|
|
|
|
|
|
Electrostatic Discharge Immunity |
|
Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3) |
|
Grounding |
|
Functional grounding: Grounding resistance of 100Ω, 2mm² (AWG 14) or thicker |
|
|
wire, or your country's applicable standard. (Same for FG and SG terminals) |
|
|
|
|
|
|
Structure *1 |
|
Equivalent to IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly |
|
|
installed in an enclosure) |
|
|
|
|
|
|
Cooling Method |
|
Natural air circulation |
|
Weight Approx. |
|
1.2 kg [2.6 lb] or less (display unit only) |
|
External Dimensions |
|
W218 x H174 x D60 mm [W8.58 x H6.85 x D2.36 in.] |
|
Panel Cut Dimensions *2 |
|
W204.5 x H159.5 mm [W8.05 x H6.28 in.], Panel thickness area: 1.6 to 5 mm |
|
|
[0.06 to 0.2 in.] |
|
|
|
|
|
*1:The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP unit, be sure to confirm the type of conditions that will be present in the GP's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket
*2:Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].
--------------------------------------------------------
CTY TNHH KỸ THUẬT ĐIỆN THÀNH PHÁT
Hotline: 0967.127.303
Email: info@dienthanhphat.com or kinhdoanh.dienthanhphat@gmail.com
Website: www.dienthanhphat.com