SPECIFICATION

 

 

 

 

 

NES-100-5

NES-100-7.5

NES-100-9

 

NES-100-12

NES-100-15

NES-100-24

NES-100-48

 

 

 

 

 

 

 

 

 

 

 

DC VOLTAGE

 

5V

7.5V

 

9V

 

12V

15V

24V

48V

RATED CURRENT

 

20A

13.6A

 

11.2A

 

8.5A

7A

4.5A

2.3A

CURRENT RANGE

 

0 ~ 20A

0 ~ 13.6A

 

0 ~ 11.2A

 

0 ~ 8.5A

0 ~ 7A

0 ~ 4.5A

0 ~ 2.3A

RATED POWER

 

100W

102W

 

100.8W

 

102W

105W

108W

110.4W

RIPPLE & NOISE (max.) Note.2

80mVp-p

120mVp-p

 

120mVp-p

 

120mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

 

4.75 ~ 5.5V

7.13 ~ 8.3V

 

8.55 ~ 9.9V

 

11.4 ~ 13.2V

14.25 ~ 16.5V

22.8 ~ 26.4V

45.6 ~ 52.8V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

 

±1.0%

 

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

Note.4

±0.5%

±0.5%

 

±0.5%

 

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION

Note.5

±0.5%

±0.5%

 

±0.5%

 

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

 

1000ms, 20ms/230VAC

1000ms, 20ms/115VAC at full load

 

 

 

HOLD UP TIME (Typ.)

 

30ms/230VAC

25ms/115VAC at full load

 

 

 

 

 

VOLTAGE RANGE

Note.8

85 ~ 132VAC / 176 ~ 264VAC selected by switch

248 ~ 373VDC

 

 

 

FREQUENCY RANGE

 

47 ~ 63Hz

 

 

 

 

 

 

 

 

EFFICIENCY (Typ.)

 

80%

81%

 

81%

 

83%

84%

86%

86%

AC CURRENT (Typ.)

 

2A/115VAC

1.2A/230VAC

 

 

 

 

 

 

INRUSH CURRENT (Typ.)

COLD START 45A

 

 

 

 

 

 

 

LEAKAGE CURRENT

 

<2mA / 240VAC

 

 

 

 

 

 

 

 

OVERLOAD

 

110 ~ 150% rated output power

 

 

 

 

 

 

 

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

 

 

 

 

 

OVER VOLTAGE

 

5.75 ~ 6.75V

8.6 ~ 10.1V

10.4 ~ 12.2V

 

13.8 ~ 16.2V

17.25 ~ 20.25V

27.6 ~ 32.4V

55.2 ~ 64.8V

 

Protection type : Hiccup mode, recovers automatically after fault condition is removed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WORKING TEMP.

 

-20 ~ +60℃ (Refer to "Derating Curve")

 

 

 

 

 

WORKING HUMIDITY

 

20 ~ 90% RH non-condensing

 

 

 

 

 

 

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH

 

 

 

 

 

 

 

TEMP. COEFFICIENT

 

±0.03%/℃ (0 ~ 50℃)

 

 

 

 

 

 

 

VIBRATION

 

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

 

SAFETY STANDARDS

Note.6

UL60950-1, CB(IEC60950-1),CCC GB4943.1:2011 approved

 

 

 

WITHSTAND VOLTAGE

 

I/P-O/P:3KVAC

I/P-FG:2KVAC   O/P-FG:0.5KVAC

 

 

 

 

 

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

 

 

 

EMC EMISSION

 

Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3

 

 

 

EMC IMMUNITY

 

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A

 

MTBF

 

320.7Khrs min.

MIL-HDBK-217F (25℃)

 

 

 

 

 

DIMENSION

 

159*97*38mm (L*W*H)

 

 

 

 

 

 

 

PACKING

 

0.55Kg; 30pcs/17.5Kg/0.97CUFT

 

 

 

 

 

 

  1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 
  1. Tolerance : includes set up tolerance, line regulation and load regulation. 
  1. Line regulation is measured from low line to high line at rated load. 
  1. Load regulation is measured from 0% to 100% rated load. 
  1. For the request of GB4943.1,the power supply is only suitable for use in the altitude 2000m below and the non tropical climate condition. 
  1. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com) 
  1. When using DC voltage as the input, please connect positive pole of input voltage to mark “N” of the terminal block and negative pole of input voltage to mark “L” of the terminal block.

--------------------------------------------------------

CTY TNHH KỸ THUẬT ĐIỆN THÀNH PHÁT 

Hotline: 0967.127.303

Email: info@dienthanhphat.com or kinhdoanh.dienthanhphat@gmail.com

Website: www.dienthanhphat.com

 

 

Sản phẩm liên quan

Danh Mục Bài Viết


facebook Chat Live Facebook
chat_facebook